What are the principles of structural knock down house

Principles of designing a single-storey knock-down house pillar or building a one-story house steel used to make poles of a single-storey knock-down house Start as a building or a small shop. Small knock-down house The usable area is less than 9 square meters, such as guard towers, shop kiosks, small offices, size 2×2 m., 2×3 m. or 3×3 m. The column size is 3×3 inches, 2.3 mm. thick and 3.2 mm. height. Not more than 1.125 m. according to the budget and the use of steel symbol 75x75x2.3 mm. or 75x75x3.2 mm.

house building affiliation trendyhome.co.th  It is a prominent relationship in the home development business for quite a while. We have in excess of 5000 houses worked in Thailand.

Note, because the pole is the whole load and is exposed to water, sunlight and high humidity, use a thickness of 3.2 mm., the better.

The formula for estimating the width of the column is equal to the height of the elevation 15.

Steel box pole, size 3×3 inches, thickness 2.3 – 3.2 mm., height not more than 1.15 m.

steel used to make poles Of a single-storey knock-down house, medium size 9-40 sq m. is a knock-down house, size 3×3 m. 3×4 m. 3×5 m. 3×6 m. 3.5×6 m. using 4×4 inches, 2.3 mm. and 3.2 mm. thick. Elevation not more than 1.5 m. Steel symbol 100x100x2.3 mm./ 100x100x3.2 mm. Use column size 6×6 inches, thickness 2.3 mm. and 3.2 mm. Elevation height not over 2.25 m. Steel symbol 150x150x2.3 mm/ 150x150x3 .2 mm. according to budget and usage

Note, because the pole is the whole load and is exposed to water, sunlight and high humidity, use a thickness of 3.2 mm., the better.

The formula for estimating the width of the column is equal to the height of the elevation 15.

Steel box pole, size 4×4 inches, 6×6 inches, thickness 2.3 – 3.2 mm.

steel used to make poles Of a single-storey knock-down house, medium size 9 – 40 sq m. is a knock-down house, size 3×6 m. 3.5×6 m. 4x6m., raised height 60-100 cm., using columns size 5×5 inches, thickness 2.3 mm. and 3.2 mm. . Elevation not more than 1.875 m. Steel symbol 125x125x2.3 mm. or 125x125x3.2 mm.

Use pole size 6×6 inches, thickness 2.3 mm. and 3.2 mm., height not more than 2.25 m.

Steel symbol 150x150x2.3 mm. or 150x150x3.2 mm. according to budget and usage

Note because the pole is to support all the weight and is exposed to water, sunlight and high humidity. Use a thickness of 3.2 mm., the better.

The formula for estimating the width of the column is equal to the height of the elevation 15.

Steel box poles, size 5×5 inches / 6×6 inches, thickness 2.3-3.2 mm., for making poles with a height of 0.6-1.0 m. In case of heights greater than 1.0 m., must have a special pole design or change to use NCPO poles instead. Stronger and more resistant to moisture

steel used to make poles The big one-storey knock-down house is the knock-down house. building a one-story house with size over 40 sq.m., use building poles, use steel boxes size 4×4 inches / 5×5 inches / 6×6 inches. Instead of steel poles, poles, poles, NESDB, lifting height 60-200 cm., should use 6-12 inches in front as appropriate.

Remarks: because the NSO’s poles are suitable for permanent buildings that do not wish to move It will bear the weight and withstand moisture better. Steel box stanchion pole pole, suitable for large knock-down houses or lifting height over 1 m.

knock down house Two types of poles can be designed.

1. Design to show the steel column outside.

   “We must always install the steel frame on the wall along the inner beam” The advantage is that we will not see the corner of the pillar inside. Easy design to match the size of the material. no yellow scrap material

2. The design does not show the steel pole.

   “We will always install the steel frame around the wall along the outside beams.” Cover the columns with cement corner covers. Advantages: exterior work looks neat, easy to store, does not require structural maintenance because it is inside, not exposed to sunlight, water and moisture

Design principles of lower beams for a single-storey knock-down house

The lower beams are important structures after the columns. have a lot of weight exposed to high humidity Therefore, the steel cross-section must be designed large and deep, thick enough.

***Recommended lower beam size is 6-8 inch double-jointed steel, 2.3 mm. or 3.2 mm. thick.

C150x50x20x2.3×6000 mm. beam distance not more than 2.25 m.

C150x50x20x3.2×6000 mm. beam distance not more than 2.25 m.

C200x75x20x3.2×6000 mm. beam distance not over 3 m.

C200x75x20x3.2×6000 mm. beam distance not over 3 m.

according to budget and usage

6-inch double-jointed C-section steel, 6-inch deep steel cross-section, making it easy to make different-level toilets. and can be installed on a 4×4 inch pole with the perfect size

 The formula for estimating the depth of the beam Main beam equal to cross length 15 Main beam equal cross length 20

poles every 2-3 meters because if the depth of the beam with the distance over the beam too far Khan has a chance to bend over or fall into the elephant’s stomach.

Example of a mobile building 6-inch C-section steel beams, double-jointed, 2.3 – 3.2 mm. thick, span not more than 3 meters.

An example of a house that uses the lower beam is a 6-inch double-jointed C-section steel, the span is 3 meters, if the beam is not more than 2.25 meters, it will match the engineering standards. both strength and longer service life

The case is a building that does not weigh much. a temporary building The minimum lower beam should use a 4×4 inch steel box because it has a cross-section that can be installed easily and strongly.